Installation manual
Série 32 Mlift Vector - Prog.Vectorielle Installation manual Chapter VI - page 27
STANDARD PROGRAMMING
EXAMPLE:
Configuration for an installation of 8 LEVELS including 2 BASEMENT.
If at Level 2 - Ground Level (Address 2A), we desire « RC » displayed, we program 1C to parameter
address 2A (REPTxx : REPeaTer at level xx).
Level Address
15 37
14 36
13 35
12 34
11 33
10 32
931
830
72F
62E
52d
42C
32b
2 2A
129
028
Displayed on
digital indicator
Code to be
programmed
into the
controller
Displayed on
digital indicator
Code to be
programmed
into the
controller
Displayed on
digital indicator
Code to be
programmed
into the
controller
000 130d ES1A
101 140E RJ1b
202 150F
RC 1C
303 1610 RH1d
404 1711 RB1E
505 1812 SS1F
606 1913 P020
707 -014 P121
808 -115 P222
909 -216 P323
10 0A -3 17 RS 24
11 0b -4 18 ME 25
12 0C -5 19
n
Select address 2A corresponding to the 2nd level with
Push buttons.
RAM
PAR
ADR/DON
MODIF
1
o
1 second later, a value is displayed, if this value suits you
(our example 1C) Don’t change it, if not, slide the
ADR/DON - MODIF switch to MODIF
ADR/DON
MODIF
2
p
Modify the value to obtain 1C to display « RC » at the 2nd
level.
Register the new value by pushing and releasing both
buttons at the same time.
RAM
PAR
ADR/DON
MODIF
3
q
Slide the ADR/DON - MODIF switch to ADR/DON
The new value is memorised.
ADR/DON
MODIF
4