Installation manual

Série 32 Mlift Vector - Prog.Vectorielle Installation manual Chapter I - page 12
HOW TO INSTALL THE CONTROLLER CABINET
SUPPORT BAR
fixing with 2 screws Ø 6,3 x 38
and wall plug Ø 8 (supplied).
500 mm
For resistive resistors (RR)
FURTHER BASE
model
2 to 6
For
Screws for fixing
on the wall
Cabinet
Socket
controller
with RR>4
For
Hinged door (Left or right)
Controller dimensions : L = 750 mm, H = 1050 mm, D = 300 mm
Controller dimensions with a lot of Extra Items : L = 900 mm, H = 1050 mm, D = 300 mm
Separate Box for more than 4 Breaking Resistors : L = 320 mm, H =600 mm, D = 250 mm.
Protection against electrical shocks : IP 31
Don’t forget than the EN-81-1 Standard § 6.3.2.1:
6.3.2.1
The dimensions of machine rooms shall be sufficient to permit easy and safe working on
equipment, especially the electrical equipment.
In particular there shall be provided at least a clear height of 2 m at working areas, and :
a) a clear horizontal area in front of the control panels and the cabinets. This area is defined as follows :
1) depth, measured from the external surface of the enclosures, at least 0,70 m ;
2) width, the greater of the following values : 0,50 m or the full width of the cabinet or panel ;
b) a clear horizontal area of at least 0,50 m x 0,60 m for maintenance and inspection of moving parts at
points where this is necessary and, if need be, manual emergency operation (
12.5.1
).