Installation manual

Série 32 Mlift Vector - Prog.Vectorielle Installation manual Chapter VI - page 19
AUTOMATIC DOOR MOTOR PILOTED BY RETIRING RAMP
BG15
K23
+24
CAM
A2
1L1 3L2 5L3
2 T1 4 T2 6T3
A1
LP4K
09004
01
24V
I O
Telemecanique
_
+
8T4
7L4
CAM
DOOR ZONE
Factory
connected
Input
Output
Free
terminal
OR
CAR DOOR
MOTOR
ZPCAM
KT3
+
__

+RD
-RD
+CAM
-CAM
BG22
220 V INPUT
SUPPLY
The operator's power supply MUST BE CUT
by the principal switch in the machine room.
and / or by the car's electrical plug.
IT MUST NOT
therefore be supplied by the lighting circuit
Forbiden
to open
between level
(EN 81 § 7.7.3)
Explaination
(CEN n°227)
Automatic door motor piloted by retiring ramp
CAM
Retiring ramp
Add.
13
Seg.
3
RAM
PAR
ADR/DON
MODIF
Retiring ramp output preview