System information
Installing Hardware Options
3-10
MicroVAX 3100 Models 88/98 User Information
ML013593
Figure 3-6 Removing the Front Bezel
4. Remove the EMI shield covering the slot you are filling by pushing it out from the
inside of the enclosure. Refer to Figure 3-7, Item .
5. Attach the drive rail, Figure 3-7, Item onto the device (or onto the mounted bracket
if you are installing a 3.5-inch device) using the screws provided.
6. Insert the rear of the device through the front of the bay and slide it rearward in the
bay, engaging the bay tabs onto the drive rail. If you are installing a non-removable
media device (such as a disk drive) seat it so that the front is flush with the front of the