System information
Getting Started
MicroVAX 3100 Models 88/98 User Information
2-33
__________________________ Note _____________________________
Before removing the system unit from a network:
• Get the approval of the network coordinator.
• See the operating system documentation for
information on the shutdown procedures before
stopping or turning off the system.
• If the system is the server in a network, do not turn off,
halt or restart the system without notifying the other
network members.
____________________________________________________________
Removing the System Unit from a ThinWire Ethernet Cable
To remove the system unit from a ThinWire Ethernet cable,
follow these steps:
1. Power the system off.
_________________________Caution ___________________________
Disconnecting the ThinWire Ethernet terminator or the
ThinWire Ethernet cable connectors from the T-connector
may cause disruptions to network communications.
____________________________________________________________
2. Disconnect the entire T-connector from the system (see
Figure 2-10 and add a terminator to the ThinWire port on the
back of the system unit (seeFigure 2-11).
Removing the System Unit from a ThickWire Ethernet Cable
To remove the system unit from a ThickWire Ethernet cable,
follow these steps:
1. Power the system off.
2. Disconnect the transceiver cable from the ThickWire
Ethernet connector on the back of the system unit (see Figure
2-11 and replace it with a terminator (see Figure 2-10).