System information

Technical Specifications
MicroVax 3100 Models 88/98 User Information
E-3
Table E-2 Acoustic Levels
Product Sound Power Level
L
WAd
, B
Idle Operate
Sound Pressure Level
L
p
Am
, dBA
(Operator Position)
Idle Operate
Model 88/98
diskless system
enclosure
5.6 5.6 36 36
Per device when installed in system enclosure
RZ28D 5.9 6.2 40 43
RZ26N 5.9 6.2 40 43
RZ29B 5.9 6.2 40 43
__________________________NOTE ____________________________
Current values for specific configurations are available from Digital
representatives. 1B=10 dBa.
____________________________________________________________
Table E-3 System Unit Metrics
System Unit
Weight
kg (lb)
Height
cm (In)
Width
cm (In)
Depth
cm (In)
Models 88/98 15.9 kg (35 lb.) 41 cm (16 in.) 22 cm (8.7 in.) 47.5 cm (18.7 in.)
Depends on the configuration. The value shown in this table is a typical value. Values vary
depending on the options that you install.
Table E-4 System Operating and Nonoperating Conditions
Operating Conditions Range or Value
Temperature range
10
°
C (50
°
F) to 40
°
C (104
°
F)
Temperature change rate
11
°
C (20
°
F) per hour maximum
Relative humidity 20% to 90% non-condensing
Maximum wet bulb temperature
28
°