System information

Console Commands
MicroVax 3100 Models 88/98 User Information
A-23
Arguments:
[address] The address at which to begin execution. This address is
loaded into the user's PC.
Example:
>>> START 1000
TEST
The TEST command invokes a diagnostic test program specified by the test number. If
you enter a test number of 0 (zero), all tests that are allowed to be executed from the
console terminal are executed. The console accepts an optional list of up to five additional
hexadecimal arguments.
You can see a full listing of all the tests by running test 9E.
Format:
TEST [{test_number} [{test_arguments}]]
Arguments:
{test_number} A two-digit hexadecimal number specifying the test to be
executed. Test 9E displays a full list of all the available
tests and their parameters.
{test_arguments} Up to five additional test arguments. These arguments
are accepted, but the console cannot interpret them.
Example:
>>> TEST 0
70..69..68..67..66..65..64..63..62..61..60..59..58..57..56..55..
54..53..52..51..50..49..48..47..46..45..44..43..42..41..40..39..
38..37..36..35..34..33..32..31..30..29..28..27..26..25..24..23..
22..21..20..19..18..17..16..15..14..13..12..11..10..09..08..07..
06..05..04..03..
Tests completed.