System information
Diagnostic Tests and Commands
5–16
MicroVAX 3100 Models 88/98 User Information
Device Status Column
SCSI Ids and SCSI Device Names
The test numbers listed identify the normal test or script number to run to verify the device
listed. There are additional tests and utilities for some devices. Test 0 calls the power-up
script.
_________________________ NOTE____________________________
The lines for F0, E8 and EC display only if the applicable option is present.
___________________________________________________________
If the system detects errors in the most recent power-up tests and diagnostic utilities, it
responds with a configuration display similar to the following:
KA58-A or KA59-A V1.0, VMB 2.16
08-00-2B-2B-16-91
64MB
TstNbr DevNam Info
------ -------- --------------------------
0 CPU_BD OK
A8 MEMORY OK
E4 DZ ?? 001 0048
E0 SCSI OK
3-RZ26N 4-RRD45 6-Adapter
5F NI OK
E8 COMM OK
DSW41/42 2 CHANNEL V3.11-47
EC ASYNC OK
DHW41/2 V1.6