System information

Diagnostic Tests and Commands
5–14
MicroVAX 3100 Models 88/98 User Information
Example 6
The following example represents a case where there are two SIMM carriers installed and
the SIMM is defective or not installed on one the carriers.
KA58-A or KA59-A V1.0, VMB 2.16
Performing normal system tests.
71..70..69..68..67..66..65..64..63..62..61..60..59..58..57..56..
55..54..53..52..51..50..49..48..47..46..45..44..43..42..41..40..
39..38..37..36..35..34..33..32..31..
? Test_Subtest_40_06 Loop_Subtest=00 Err_Type+FF DE_Memory_count_pages.lis
30..29..28..27..26..25..24..23..22..21..20..19..18..17..16..15.
14..13..12..11..10..09..08..07..06..05..04..03..
Memory set 1: 00000000 to 00FFFFFF, 64MBs, 131072 good pages, 0 bad pages
Set 1 on SIMM_carrier_J4 (J1...) (J2...) (J3...) (J4...)
Memory set 2: 04000000 to 0BFFFFFF, 128MBs, 0 good pages, 262144 bad pages
Set 2 on SIMM_carrier_J1 (J5...) (J6...) (J7 ??) (J8...)
Memory set 3: 0C000000 to 13FFFFFF , 128MBs, 262144 good pages, 0 bad pages
Set 3 on SIMM_carrier_J1 (J1...) (J2...) (J3...) (J4...)
Total of 320MBs, 393216 good pages, 262144 bad pages, 15 reserved pages
Tests completed.
This SIMM on J7 of the SIMM carrier installed on J1 of the CPU is bad or not installed.
Configuration Display
The configuration display shows the system configuration and the error messages that were
detected while the most recent power-up tests, diagnostic tests, and utilities were running.
If you add expansion boxes to the system and do not run the power-up tests or appropriate
diagnostic test or utility, the configuration display does not recognize the reconfiguration.