System information
Diagnostic Tests and Commands
MicroVAX 3100 Models 88/98 User Information
5–9
You must enter three zeros (0) as place holders for the three parameters that occur before
the user-specified parameter, mark_hard_SBEs. The last value (1) is a parameter. You
can then specify the mark_hard_SBEs parameter in the Memory_Init_Bitmap
test as follows:
>>> T 30 0 0 0 1
The resulting messages differ, depending on the function of the test or utility. However,
most failing tests cause the system to display error messages similar to the following:
>>> T 5F 1
? Test_Subtest_5F_18 Loop_Subtest=0E Err_Type=FF DE_SGEC.lis
Vec=010C Prev_Errs=0000 P1=00000001 P2=00000000 P3=827DFF03 P4=00000000
P5=00000000 P6=00000000 P7=00000000 P8=00000001 P9=00000000 P10=00000000
r0=00000054 r1=000082E2 r2=00000001 r3=000082FA r4=00008230 r5=00000040
r6=000082E2 r7=20008000 r8=00008000 r9=20140758 r10=13000001 r11=2014044B
EPC=2005721A dser=0000 cesr=00000000 icsr=01 pcsts=F800 pcctl=FC13
cctl=00000007 bcetsts=03A0 bcedsts=0400 cefsts=00019200 nests=00
mmcdsr=00C6C600 mesr=00006000
>>>
Write down the error messages before you contact your Digital services representative.
Power-Up Error Messages
The following are examples of some error messages at power-up.
Example 1
The following is a typical example of a failed test. In this case, test E8 failed testing a
SYNC (COMM) option.
KA58-A or KA59-A V1.0, VMB 2.16
Performing normal system tests.
74..73..72..71..70..69..68..67..66..65..64..63..62..61..60..59..
58..57..56..55..54..53..52..51..50..49..48..47..46..45..44..43..