System information
Diagnostic Tests and Commands
5–4
MicroVAX 3100 Models 88/98 User Information
Operating system messages start here.
Abbreviated error message for memory error
Memory errors normally cause the results of a SHOW MEMORY display to occur after the
tests are completed and before continuing. SHOW MEMORY is the most useful command
to determine which memory SIMMs are bad when memory errors occur.
Diagnostic Tests and Utilities
The diagnostic tests and utilities are similar to the power-up tests except that the power-up
tests enable you to test all the devices in the system, whereas the diagnostic tests and
utilities enable you to test single devices and the functions of single devices.
By entering this command, you can see a list of diagnostic tests.
>>> T 9E
>>> SHOW TESTS
Test
# Address Name Parameters
___________________________________________________________________________
20052200 SCB
20055850 De_executive
30 2006A53C Memory_Init_Bitmap *** mark_Hard_SBEs ******
31 2006AB34 Memory_Setup_CSRs *********
32 2005D148 NMC_registers **********
33 2005D324 NMC_powerup **
34 2005E6D8 SSC_ROM ***
35 2005FB90 B_Cache_diag_mode bypass_test_mask *********
37 20061590 Cache_w_Memory bypass_test_mask *********
40 2006B5E0 Memory_count_pages First_set Last_set Soft_errs_allowed *****
41 20068CEC Board_Reset *
42 20061880 Chk_for_Interrupts **********
46 200610C4 P_Cache_diag_mode bypass_test_mask *********
47 2006AD04 Memory_Refresh start_a end incr cont_on_err time_seconds *****
48 2006B028 Memory_Addr_shorts start_add end_add * cont_on_err pat2 pat3 ****