System information

Diagnostic Tests and Commands
5–2
MicroVAX 3100 Models 88/98 User Information
Tests completed.
>>>
Central Processing Unit (CPU) Name, Firmware Version Number, and
Virtual Memory Boot (VMB) Version Number
Read-Only Memory (ROM) Based Diagnostics Countdown Status Message
Console Prompt
The following example shows a typical display for a system that passes all tests and then
enters automatic bootstrap.
KA58-A or KA59-A V1.0, VMB 2.16
Performing normal system tests.
74..73..72..71..70..69..68..67..66..65..64..63..62..61..60..59..
58..57..56..55..54..53..52..51..50..49..48..47..46..45..44..43..
42..41..40..39..38..37..36..35..34..33..32..31..30..29..28..27..
26..25..24..23..22..21..20..19..18..17..16..15..14..13..12..11..
10..09..08..07..06..05..04..03..
Tests completed.
Loading system software.
(BOOT/R5:0 EZA0)
2..
-EZA0
1..0..
_________________________ NOTE____________________________
The operating system messages start here.
___________________________________________________________
If the power-up tests encounter an error, one of the following actions occurs:
For minor errors:
If HALT action is set to a boot condition (that is reboot or restart_reboot), and if a
minor error occurs, the system displays an abbreviated error message and continues to
boot as normal.