System information

Diagnostic Tests and Commands
VAX 4000 Model 108 User Information
6–3
Diagnostic Self-Tests and Utilities
Self-tests perform the same tests as the power-up tests except for one difference; the
power-up tests test all the devices in the system, whereas the self-tests allow you to test a
single device.
Execution of the SHOW CONFIG command produces the display showing the failure of
the device DZ, shown as follows.
>>>SHOW CONF
KA57-A V1.0, VMB 2.16
08-00-2B-2B-16-91
64MB
TstNbr DevNam Info
------ -------- --------------------------
0 CPU_BD OK
A8 MEMORY OK
E4 DZ ?? 001 0048
E0 SCSI OK
3-RZ28D 4-RRD45 6-Adapter
5F NI OK
5C DSSI OK
0 QBUS OK
E8 COMM OK
DSW41/42 2 CHANNEL V3.11-47
EC ASYNC OK
DHW41/2 V1.6
>>>
Listing showing failure of DZ
If you encounter an error in the power-up test display or the show configuration display,
follow these specific steps: