Stopping the engine
It is recommended that you run the engine for a few minutes at min-
imum speed and with no load before stopping it; this will allow the
temperature to drop evenly and will avoid harmful thermal shocks.
A. The engine is stopped from the main IVECO MOTORS control
panel by turning the key switch to the rest position 8A.
B. The IVECO MOTORS secondary control panel is stopped by
pressing the red button (6) on the control panel.
The layout of this engine foresees the presence, either in or near the
engine room, of a button that can be pressed to stop the engine in an
emergency, using “excited” logic (as required or prescribed by the
certification Bodies).
To re-start the engine from the main control panel:
1. Return the key switch to the rest position 8A to reset all the on-
board control panel functions.
2. Proceed as described previously.
To re-start the engine from the secondary control panel:
1. Make sure that the panel has been enabled (key switch on the main
control panel turned to position 8B).
2. Press the green button (5) and release it; when the engine has
started, make sure that the rev indicator is showing a plausible
reading.