Technical data

9
ENGLISH
USE
PRELIMINARY CHECKS
Before starting the engine each time:
Make sure that the sea-water inlet valve is open. Operation of the
sea water pump without water would cause irreparable damage to
the internal rotor within a very few seconds.
Check the level of technical fluids (fuel, engine oil and coolant).
STARTING AND STOPPING THE ENGINE
For vessels equipped with instrument panels that
are not manufactured by IVECO MOTORS
The start-up and shut-down operations described in the following pag-
es apply to an on-board control panel manufactured by IVECO MO-
TORS; if the vessel is fitted with an instrument panel that has been
customised by the Boatbuilder or Fitter, these operations may vary ac-
cording to the various choices made during construction. In these cas-
es, follow the start-up/shut-down sequence and use the instrument
panel description provided by the Boatbuilder on specific documenta-
tion.
For engines fitted with an electric pre-lubrication
system
Press the engine electric system power switch to start the pre-lubrica-
tion function, for which the relevant indicator light will turn on.
Start-up of the engine, as described in the following pages, must only
take place after allowing a sufficient amount of time to complete pre-
lubrication, or after the indicator light has gone out.
Electronic pre-lubrication module
A. - B. Commands not active
CAUTION!
Before starting the engine, make sure that no combustible
vapours or gasses are present in the engineroom.
WARNING
Start-up and shut-down of this engine are managed entirely by the
Electronic Control Unit; the start-up phase commences when the rel-
evant buttons or switches are released.
/&&#(!2'%
%6$)3#(!2'%
/.
%6
04_037_C
A
B