SIMOVERT MASTERDRIVES Operating Instructions 9-1
9 Parameterizing steps
In general, parameterization can be subdivided into the following main
steps:
1. Power section definition (P060) = 8)
2. Board definition (P060 = 4)
3. Drive definition (P060 = 5)
4. Function adjustment.
Not all parameterizing steps have to be run through in detail in each
case during start-up. It is possible under certain conditions to combine
some of the steps and shorten parameterization by using quick
procedures. The following quick procedures are possible:
1. Parameterizing with user settings
(Fixed setting or factory setting, P060 = 2)
2. Parameterizing with existing parameter files
(Download, P060 = 6)
3. Parameterizing with paramater modules
(Quick parameterization, P060 = 3)
Depending on the specific prevailing conditions, parameterization can
be carried out either in detail or in accordance with one of the specified
quick procedures.
By activating a fixed setting (P060 = 2), the parameters of the unit can
also be reset to the original values.
Detailed
parameterization
Quic
k
parameterization