Operating instructions

Vector Control Chassis Type Frequency Converter Faults and Alarms
SIEMENS AG 476 869 4070 76 J AB-74
SIMOVERT MASTERDRIVES Operating Instructions 11-23
Fatal errors are serious hardware or software errors which no longer
permit normal operation of the unit. They only appear on the PMU in
the form "FF<No>". The software is re-booted by actuating any key on
the PMU.
FFxx Error message Power-down the converter and power-up
again. Call the service personnel if a fatal
error message is displayed again
FF01 Time slot overflow
A non-removable time sector overflow was
identified in the higher priority time sectors.
Increase sampling time (P357) or reduce
pulse frequency (P340)
Replace CU
FF03 Access error, optional board
Fatal errors occurred when accessing
external optional boards
(CB, TB, SCB, TSY ..)
Replace CU
Replace LBA
Replace optional board
FF06 Stack overflow
Overflow of the stack.
Increase sampling time (P357) or reduce
pulse frequency (P340)
Replace CU
FFxx Other fatal errors Replace CU
E Fatal hardware errors Replace CU
EEEE Fatal firmware errors Replace CU
Re-load firmware
Table 11-3 Fatal errors
Fatal errors (FF)