user manual
Single-path instrument
Applies if the instrument is equipped with one RF path and no more than one baseband path.
Step c Configure RF path MANDATORY
Choose frequency range (only one choice possible) MANDATORY
Option Description Requires Not compatible with HW or SW Remarks
SMATEB103 100 kHz to 3 GHz SMATE200A SMATEB106 HW Factory-installed
SMATEB106 100 kHz to 6 GHz SMATE200A SMATEB103 HW Factory-installed
Choose output configuration OPTIONAL
Option Description Requires Not compatible with HW or SW Remarks
SMATE-B22 Low Phase Noise and analog
modulation FM and PhiM
SMATEB10x - HW Factory-installed
SMATE-B31 High-Power Output SMATEB10x - HW Factory-installed
Step d Configure baseband path OPTIONAL
Choose baseband source MANDATORY
Option Description Requires Not compatible with HW or SW Remarks
SMATE-B13 Baseband Main Module SMATEB10x - HW Factory-installed.
Requires SMATEB10, SMATE-B11 or SMATEK62.
SMATE-B10
Baseband Generator with
ARB (64 MSamples) and
Digital Modulation
SMATE-B13 SMATEB11 HW Factory-installed
SMATE-B11 Baseband Generator with
ARB (16 MSamples) and
Digital Modulation
SMATE-B13 SMATEB10 HW Factory-installed
Choose baseband hardware OPTIONAL
SMATE-B16 Differential I/Q Output SMATE-B10 or B11 - HW Factory-installed
Choose digital modulation systems OPTIONAL
Option Description Requires Not compatible with HW or SW Remarks
SMATE-K40 Dig. Std. GSM/EDGE SMATE-B10 or B11 - SW
SMATE-K42 Dig. Std. 3GPP FDD SMATE-B10 or B11 - SW
SMATE-K43 3GPP enhanced MS/BS tests
incl. HSDPA
SMATE-K42 - SW
SMATE-K46 Dig. Std. CDMA2000 SMATE-B10 or B11 - SW
SMATE-K61 Multicarrier CW Signal
Generation
SMATE-B10 or B11 - SW