Full Product Manual
36
allowed number of slaves
4D01
Circuit Breaker Open
4D02
Circuit Breaker Welded
4D03
DC Link Collapsed
4D04
Circuit Breaker Timeout
Time to close breaker of GpAC
has expired
4D41
Motor Isolation Fault
Motor isolation contactor is
open circuit
4D42
Motor Open Circuit Fault
Motor terminal is open circuit or
disconnected from controller
4D43
Motor stalled No speed feedback from motor
4DC3
Power Supply Critical
Battery voltage has dropped
below critical level
4E81
RPDO Timeout (severe)
One or more configured RPDOs
not received with 3s at start up
or 500ms during normal
operation.
4EC1
Cant Establish Fld Curr
Controller is unable to control a
current in the field winding
4EC2
Pulsing Disabled
The motor control protection
subsystem unexpectedly
disabled the PWM
4F01
Unexpected slave state
CANopen slave has changed to
unexpected state
4F02
EMCY send failed
Unable to transmit EMCY
message
4F41
Internal Fault Internal software fault
4F42
Out of memory Out of memory
4F43
General DSP error
Unknown error raised by motor
model code
4F44
Timer Failed Unable to allocate timer
4F45
Queue Error
Unable to post message to
queue
4F46
Scheduler Error
Unable to create task in
scheduler
4F47
DSP Heartbeat Error
Communication lost between
host and DSP processors
4F48
I/O SS Error Internal software fault
4F49
GIO SS Error Internal software fault
4F4A
LCM SS Error Internal software fault
4F4B
LCP SS Error Internal software fault
4F4C
OBD SS Error Internal software fault
4F4D
VA SS Error Internal software fault
4F4E
DMC SS Error Internal software fault
4F4F
TracApp SS Error Internal software fault
4F50
New Powerframe Detected New power frame detected.
4F51
DSP Not Detected
Communication lost between
host and DSP processors
4F52
DSP Comms Error
Communication lost between
host and DSP processors (or
IOP and MCP)
4F53
App Manager SS Error Internal software fault
4F54
Autozero range error
Current sensor auto-zero
current out of range
4F55
DSP parameter error
Communication error between
host and DSP processors