46C1
Encoder Alignment Warning Encoder is not aligned properly.
46C2
SinCos Tracking Warning
SinCos Encoder Min Max
Values are heading towards a
voltage rail or converging
together.
46C3
Fault Ride Through
A fault ride through event has
been encountered, but
operation is allowed to continue
although the system may be
derated
46C4
Motor Pull-Out Warning
The open loop VF induction
motor software has detected a
pulled-out condition, it will
automatically attempt to restart.
46C5
Stator Resistance Error
Stator resistance thermal
compensation has failed due to
the estimated value being too
different from the configured
value
46C6
Encoder PLL Deactivated
Warning
Encoder PLL has turned off due
to poor tracking
4701
CAN warning
Vehicle is operating in reduced
power mode as some CAN
messages are not being
received (Renault only)
4741
Scheduler stack overflow
warning
This warning is set if any task
has between 10% and 20% of
its stack free.
4742
Internal supply out of range
warning
An internal logic supply rail has
gone out of range
4781
CANopen anon EMCY level 1
EMCY message received from
non-Sevcon node and
anonymous EMCY level
(0x2830,0) is set to 1.
4782
24V Supply Low
4783
24V Supply High
47C1
Vehicle Service Required
Vehicle service next due time
(0x2850,5) has expired. If
supported Service driveability
profile (0x2925) will activate.
4881
Seat Fault
Valid direction selected with
operator not seated or operator
is not seated for a user
configurable time in drive.
4882
Two Direction Fault
Both the forward and reverse
switches have been active
simultaneously for greater than
200 ms.
4883
SRO Fault
FS1 active for user configurable
delay (0x2914,2) without a
direction selected.
4884
Sequence Fault
Any drive switch active at power
up.
4885
FS1 Recycle Fault
FS1 active after a direction
change and FS1 recycle
function enabled (0x2914,1 bit