5.1 AC RECHARGE
During Recharge:
a) Never turn on while charging.
b) Make sure the AC power source is 120 volts, 60 Hz.
c) After recharge – disconnect cord and wait 5 minutes before use.
5.2 CHARGING INDICATORS
Unit includes charging indicator LED’s that display battery level of charge any
time during operation or storage by simply turning ON the area light. LED’s
willl light under the following conditions:
1. Automatically during AC recharge.
2. During area light operation.
During AC recharge green LED will blink when charging is complete. Wait 5
minutes after disconnecting charger to operate unit.
FIGURE 2 - AC CHARGER
WARNING: Use the supplied AC recharge adapter; do not substitute. AC recharg-
ing requires the use of the included AC charger/adapter that supplies
12 volts DC.
1. Connect the AC charger to an AC power source.
2. Plug the adapter’s barrel connecter into the AC recharge port located near the
handle.
3. Recharge for 15 hours maximum.
4. After recharge, disconnect the barrel connector from the recharge port and store the
adapter.
5.3 DC RECHARGE
a) Maximum charge - 5 hours
b) After recharge – disconnect cord and wait 5 minutes before use.
FIGURE 3 - DC CHARGER
Make sure the DC source (jump starter, battery pack, vehicle accessory socket, etc) is
12 volt DC. The DC source should be able to supply at least 10 amps at 12 volt DC.
VEC184POB Manual 7/15 7/16/04 10:04 AM Page 4