PECC
outlet
PE
PEP
PECC
contactors control
&
HVDC
CP supervision
CP signal
Figure 8: vSECC safety output
Control Pilot supervision: The EV communicates the charging state via the CP signal to
the vSECC. Depending on this state, the power electronics (PE) may or may not energize
its outlet. The CP signal is processed and provided as safety output directly to the power
electronics. There, a logical AND conjunction of the input from the power electronics com-
munication controller (PECC) and the vSECC safety output controls the high-voltage DC
module (HVDC) output.
2.2.6 X305 - CAN
Figure 9: vSECC connector: X305
This connector will be used for planned features coming with future software re-
leases.
© Vector Informatik GmbH Version 1.2.0 23