User's Manual
User Manual VC-EVCC
© 2021 Vector Informatik GmbH Version 1.3.0 95
5.2.1.2.12 Configuration of Plug and Charge
The VC-EVCC provides the possibility to use Plug and Charge (PnC) according to ISO
15118. The following DIDs are used for the Plug and Charge configuration of the VC-EVCC.
PnC Activation:
DID FD 26 – Configuration PnC Activation
PnC Certificates/Private Keys:
DID FD 27 – Configuration OEM Provisioning Certificate
DID FD 28 – Configuration OEM Provisioning Certificate Private Key
DID FD 29 – Configuration OEM Provisioning Certificate and Private Key
DID FD 2A – Configuration PnC Contract Certificate
DID FD 2B – Configuration PnC Contract Certificate Private Key
DID FD 2C – Configuration PnC Contract Certificate and Private Key
DID FD 2D – Configuration PnC Sub Certificate
DID FD 2F – Configuration PnC Root Certificate
5.2.1.2.12.1 Configuration of Plug and Charge Activation/Deactivation
Plug and Charge can be activated via UDS as described in this chapter.
The service structure is defined as 1 byte.
Value
Description
0x00
Plug and Charge is deactivated (default)
0x01
Plug and Charge is activated
Note
An update of the parameter requires a reboot of the VC-EVCC to be applicable.
The diagnostic service “Write Data By Identifier” is only available in the application
extended session.