5.2.1.2.7 Configuration of Secondary J1939 Source Address (Charging Arbitration)
The VC-EVCC provides the possibility to configure the Secondary J1939 Source Address.
The following source address values are available for selection
Description
Source Address Value
Secondary Source Address
0x80 (default)
Secondary Source Address
0xD7
Secondary Source Address
0xD8
Secondary Source Address
0xD9
Secondary Source Address
0xDA
Secondary Source Address
0xDB
Secondary Source Address
0xDC
Secondary Source Address
0xDD
Secondary Source Address
0xDE
Secondary Source Address
0xDF
Note
An update of the parameter requires a reboot of the VC-EVCC to be applicable.
The diagnostic service “Write Data By Identifier” is only available in the application