User's Manual

User Manual VC-EVCC
© 2021 Vector Informatik GmbH Version 1.3.0 52
Manual Configuration
Reprogramming is also possible without CANoe/CANalyzer. In this case, the following
CAN Messages (UDS/ TP) must be sent on the diagnostic CAN (CAN0) manually:
CAN-Identifier:
Tester --> VC-EVCC, Request: 0x610
VC-EVCC --> Tester, Response: 0x612
Tester --> Functional: 0x614
1. Extended Session:
Request: 02 10 03 FF FF FF FF FF
Response: 06 50 03 00 32 01 F4 FF
2. Tester Present:
Request: 02 3E 00 FF FF FF FF FF
Response: 02 7E 00 FF FF FF FF FF
Caution
The message “Tester Present” has to be sent cyclically in order to keep the VC-EVCC
in the extended session. Otherwise the extended session will be terminated after
approximately 4 – 5 seconds.
3. Message cycle time:
XX:
- 0x00: CAN Message isn’t transmitted
- 0x01 … 0xFF: CAN Message is transmitted with a cycle time of Value * 10ms
(10ms … 2550ms)
Request: 04 2E FD 0X XX FF FF FF
Response: 03 6E FD 0X FF FF FF FF
Note
In some cases the response message might include the value “AA” instead of “FF”.
The data identifiers (in blue) of CAN messages with configurable message cycle times are
listed below.
Message
Data Identifier (DID)
VCVCCU_PTC0
FD 04