User's Manual

User Manual VC-EVCC
© 2021 Vector Informatik GmbH Version 1.3.0 41
Manual Configuration
Reprogramming is also possible without CANoe/CANalyzer. In this case, the following
CAN Messages (UDS/ TP) must be sent on the diagnostic CAN (CAN0) manually:
CAN-Identifier:
Tester --> VC-EVCC, Request: 0x610
VC-EVCC --> Tester, Response: 0x612
Tester --> Functional: 0x614
1. Extended Session:
Request: 02 10 03 FF FF FF FF FF
Response: 06 50 03 00 32 01 F4 FF
2. Tester Present:
Request: 02 3E 00 FF FF FF FF FF
Response: 02 7E 00 FF FF FF FF FF
Caution
The message “Tester Present” has to be sent cyclically in order to keep the VC-EVCC
in the extended session, e.g. every second. Otherwise the extended session will be
terminated after approximately 4 – 5 seconds.
3. HSOUT0:
XX:
- 0x00: HSOUT0 isn't enabled after startup
- TTTTTT01: TTTTTT * 100ms, e.g. 33 * 100ms 0x85 (10000101)
- 0x02: HSOUT0 is enabled after startup and isn't disabled
- 0x03: HSOUT0 is enabled with respect to CP and PP
Request: 04 2E FD 03 XX FF FF FF
Response: 03 6E FD 03 FF FF FF FF
Note
In some cases the response message might include the value “AA” instead of “FF”.
In order to read the present HSOUT0 configuration, the following communication has to be
executed.
4. Read HSOUT0 configuration:
Request: 03 22 FD 03 FF FF FF FF
Response: 04 62 FD 03 XX FF FF FF