User's Manual

User Manual VC-EVCC
© 2021 Vector Informatik GmbH Version 1.3.0 36
5.2.1.2.2 Configuration of HSOUT0
The VC-EVCC gives the possibility to enable an output at startup to wake-up other ECUs.
The behavior can be configured.
By using the diagnostic service “Read Data By Identifier” (0x22) – DID 0xFD03 it is possible
to read the current configuration of the HSOUT0.
By using the diagnostic service “Write Data By Identifier” (0x2E) – DID 0xFD03 it is possible
to write the configuration of the HSOUT0.
Note
An update of the parameter requires a reboot of the VC-EVCC to be applicable.
The diagnostic service “Write Data By Identifier” is only available in the application
extended session.
The service structure is defined as 1 byte.
Value
Description
0x00
HSOUT0 isn’t enabled at startup (default)
0x01
(bin: nn nn nn 01)
HSOUT0 is enabled for a specific time at startup.
> The lower two bits of the data byte are set to 01
> The upper 6 bits leading the data are set to enable the
time: Value * 100ms
A time between 0ms and 6300 ms is configurable
0x02
HSOUT0 is enabled at startup and isn’t disabled
0x03
HSOUT0 is enabled with respect to CP and PP
Table 5-5 HSOUT0 Configuration on UDS Channel