User's Manual

User Manual VC-EVCC
© 2021 Vector Informatik GmbH Version 1.3.0 31
5.2.1.2.1 Configuration of CAN1 J1939 CAN Baud Rate
It is possible to configure the baud rate of the VC-EVCC for the J1939 vehicle CAN.
By using the diagnostic service “Read Data By Identifier” (0x22) – DID 0xFD00 it is possible
to read the current configured J1939 CAN baud rate.
By using the diagnostic service “Write Data By Identifier” (0x2E) – DID 0xFD00 it is possible
to write the J1939 CAN baud rate.
Note
An update of the parameter requires a reboot of the VC-EVCC to be applicable.
The diagnostic service “Write Data By Identifier” is only available in the application
extended session.
The service structure is defined as 1 byte, whereas the upper 6 bits are set to 0.
Value
Description
0x00
250 kBaud is configured (default)
0x01
500 kBaud is configured
0x02
1 MBaud is configured
Table 5-4 CAN1 J1939 Baud Rate Configuration on UDS Channel