User's Manual

User Manual VC-EVCC
© 2021 Vector Informatik GmbH Version 1.3.0 233
0x05E0E3*
7E005
3
PTC0
Short to VBat
0x05E0E5*
7E005
5
PTC0
Open load
0x06E0E4*
7E006
4
PTC1
Short to GND
0x06E0E3*
7E006
3
PTC1
Short to VBat
0x06E0E5*
7E006
5
PTC1
Open load
0x07E0E4*
7E007
4
PTC2
Short to GND
0x07E0E3*
7E007
3
PTC2
Short to VBat
0x07E0E5*
7E007
5
PTC2
Open load
0x0EE0EB
7E00E
0B
Diagnostic CAN (CAN0)
Bus off
0x0FE0EB
7E00F
0B
J1939 Vehicle CAN (CAN1)
Bus off
0x20E0E2
7E020
2
VCVCCU_ChargeFromVehicle
Message Timeout
0x20E0EA
7E020
0A
VCVCCU_ChargeFromVehicle
E2E Fault
0x21E0E2
7E021
2
VCVCCU_V2G_EVMaximumCurrentLimit
Message Timeout
0x22E0E2
7E022
2
VCVCCU_V2G_EVMaximumVoltageLimit
Message Timeout
0x23E0E2
7E023
2
VCVCCU_V2G_EVTargetCurrent
Message Timeout
0x24E0E2
7E024
2
VCVCCU_V2G_EVTargetVoltage
Message Timeout
0x25E0E2
7E025
2
VCVCCU_V2G_VehicleStatus
Message Timeout
0x26E0E2*
7E026
2
V2ICP_WrongConfiguration
Wrong Configuration
0x27E0E2*
7E027
2
V2ICP_CommunicationError
Communication Error
0x28E0E2*
7E028
2
VCVCCU_V2ICP_VehicleToBackend_Timeout
Message Timeout
0x29E0E2*
7E029
2
VD_Timeout
Message Timeout
0x2AE0E2*
7E02A
2
Plug and Charge Configuration Error
Wrong Configuration
0x2BE0E2
7E02B
2
Protective Earth (PE) to GND offset
Out of range
0x40E0E2
7E040
2
Hardware Software Incompatibility
Incompatibility
0x41E0E2*
7E041
2
VCVCCU_LIN_EvMaxMinCurrents
Timeout
0x42E0E2*
7E042
2
VCVCCU_LIN_EvMaxVoltageList
Timeout
0x43E0E2*
7E043
2
VCVCCU_LIN_EvMinVoltageList
Timeout
0x44E0E2*
7E044
2
VCVCCU_LIN_EvPresentCurrentList
Timeout
0x45E0E2*
7E045
2
VCVCCU_LIN_EvStatus
Timeout
Table 10-2 Diagnostic Trouble Codes