8 Device Installation
Directly install the device using three M6 hex socket head screws with a minimum
engagement length of 7.2 mm. Tighten the installation screws with a torque of M = 9.5
11.5 Nm. It is recommended to use spring washers or lock washers to secure the screws.
In general, the following minimum requirements for fastening the VC-EVCC to the vehicle
must be observed.
Screw connection: M6
Minimum engagement length of 7.2 mm in a steal thread/ nut M6 DIN934
Strength class screw: 8.8
Tightening torque: 9.5 – 11.5 Nm
Figure 8-1: Installation