User's Manual

User Manual VC-EVCC
© 2021 Vector Informatik GmbH Version 1.3.0 222
Diagnostics: Open Load in on state (min. 330mA load required)
Open Load in off state (min. 50mA load required)
Short to battery in off state
Short to Ground in on state
6.7 5A H-Bridge
This FBB represents an H-bridge to drive motor applications such as a latch where a change
in the motor direction is necessary. The FBB is capable of active freewheeling and diagnosis
in on and off state.
Nominal voltage: 12V for V
Bat
14V
>V
Bat
- 2V for V
Bat
<14V
Max. current: 5A
Switching freq.: Static on-off
Diagnostics: Open Load
Short to Ground
Short to Battery
Short between Pins
6.8 Latch Position Input
This analog input FBB determines the latch state of the inlet connector by measuring the
resistor values representing different latch states (unlocked, locked).
Meas. range: 1k(unlocked)
11kΩ (locked)
Pull up resistance: 7.5kΩ
Accuracy: ± 10%
Diagnostics: Open Load
Short to Ground
Short to Battery
Out of Range
6.9 20mA LED Output
This LED Output FBB is a constant current LED driver with three channels. Dimming can be
done via PWM up to 200Hz.
Output current: 20mA
Switching freq.: static on-off / up to 200Hz