User's Manual
User Manual VC-EVCC
© 2021 Vector Informatik GmbH Version 1.3.0 214
5.9 Charging Schedules
The VC-EVCC supports the usage of charging schedules according to ISO 15118.
5.9.1 Preconditions
The following preconditions must be fulfilled in order to use Charging Schedules with the
VC-EVCC.
Activation of Charging Schedules via UDS
The charge cable must be connected during the whole charging session including
charge pauses
The inlet must be locked during the whole charging session including charge pauses
Note
Details about the activation of Charging Schedules are included in the chapter “UDS
communication”.
5.9.2 Functionality
If all preconditions are fulfilled Charging Schedules can be used for DC charging. During a
charging session the EVSE must support and select the ISO 15118 protocol in state
SupportedAppProtocol. The VC-EVCC will always set the ISO 15118 protocol to priority 1
and DIN 70121 to priority 2.
The available SAScheduleList is transmitted by the EVSE in state
ChargeParameterDiscovery. The VC-EVCC limits the MaxEntriesSAScheduleTuple to 24
within the ChargeParameterDiscoveryReq.
The VC-EVCC will use the first SAScheduleTuple for charging and send the corresponding
SAScheduleTupleID back to the EVSE within the PowerDeliveryReq.
Note
The VC-EVCC does neither consider the SalesTariff information provided in
ChargeParameterDiscoveryRes for charging nor transmit any of the SalesTariff
information on the J1939 vehicle CAN.
The following CAN signals are used for Charging Schedules on the J1939 vehicle CAN.
VCVCCU_V2G_CurrentPMaxValue
VCVCCU_V2G_CurrentPMaxDuration
VCVCCU_V2G_CurrentPMaxMultiplier
VCVCCU_V2G_NextPMaxMultiplier
VCVCCU_V2G_NextPMaxValue
VCVCCU_Vehicle_Renegotiate