The signal VCVCCU_ChargeUnit_State is set to mode B if
LINAwake is set to 0 OR
A sleep frame has been received from EVSE via LIN OR
EVSE_StatusOp is set to Deny_V OR
LIN communication has timed out for longer than ChargeLIN_NoLinTime OR
Power outage was detected OR
ControlPilot_ChargeComActv is set to active OR
VCVCCU_Vehicle_ChargePermission is not set to allowed OR
VCVCCU_PTC0_Temperature is not PTC_NormalTemperatureAC (only if PTC0 is
activated) OR
VCVCCU_DigitalInput_DebouncedStatus is pressed OR
ChargeLin_TerminationOnError is active OR
VCVCCU_S3Switch_DebouncedStatus is pressed (only in case of Combo1) OR
VCVCCU_Vehicle_StopCharge is either pressed or error (only if StopCharge CAN
signal is activated) OR
The ECU shall end the LIN session if
VCVCCU_PlugPresent_Status is Not_Connected OR
LIN communication has timed out for longer than ChargeLIN_NoLinTime OR
Power outage was detected.
The ECU shall end the LIN session and go to sleep mode if
a LIN sleep frame has been received from the EVSE.
The ECU shall set the LIN signal EvAwake to 0 in order to request LIN sleep at EVSE if
ControlPilot_ChargeMode has changed from Mode C to Mode B OR
LINAwake changes from 1 to 0 (falling edge) OR
DigitalInput_DebouncedStatus is pressed OR
S3Switch_DebouncedStatus is pressed OR
ChargeNode_Status is not set to selected (as described in PJ-SWREQ-183476) OR
"StopCharge CAN Signal" is active and Vehicle_StopCharge is either
'Pressed' or 'Error' OR
VCVCCU_PlugPresent_Status is Not_Connected