User's Manual
User Manual VC-EVCC
© 2021 Vector Informatik GmbH Version 1.3.0 203
sets the value of the CAN signal VCVCCU_V2G_EVSEIsolationStatusFlag to 1.
5.5.8.23 Welding Detection
The VC-EVCC proceeds with WeldingDetectionReq and sets the
ControlPilot_ChargeMode to mode B if Vehicle_ContactorStatus is Opened.
5.5.8.23.1 DC_EVStatus Request Parameter
The WeldingDetectionReq is filled with the content of the received CAN signals according
to the table below.
WeldingDetectionReq
CAN signal
DC_EVChargeParameter.DC_EVStatus.EVReady
VCVCCU_V2G_EVReady
DC_EVChargeParameter.DC_EVStatus.EVErrorCode
VCVCCU_V2G_EVErrorCode
DC_EVChargeParameter.DC_EVStatus.EVRESSSOC
VCVCCU_V2G_EVRESSSOC
Table 5-65 WeldingDetectionReq CAN Signal Mapping
5.5.8.23.2 DC_EVSEStatus Response Parameter
The CAN signals are filled with the content of the corresponding WeldingDetectionRes
parameter according to the table below.
WeldingDetectionRes
CAN signal
DC_EVSEChargeParameter.
DC_EVSEStatus.EVSENotification
VCVCCU_V2G_EVSENotification
DC_EVSEChargeParameter.
DC_EVSEStatus.NotificationMaxDelay
VCVCCU_V2G_NotificationMaxDelay
DC_EVSEChargeParameter.
DC_EVSEStatus.DC_EVSEStatusCode
VCVCCU_V2G_EVSEStatusCode
DC_EVSEChargeParameter.
DC_EVSEStatus.EVSEIsolationStatus
VCVCCU_V2G_EVSEIsolationStatus
VCVCCU_V2G_EVSEIsolationStatusFlag = 1
Table 5-66 WeldingDetectionRes CAN Signal Mapping
5.5.8.23.3 Common Response Parameter
If the WeldingDetectionRes contains EVSEPresentVoltage the VC-EVCC sets the value in
the CAN signal VCVCCU_V2G_EVSEPresentVoltage.
5.5.8.24 Session Stop
The VC-EVCC proceeds with the SessionStopReq
Vehicle_ContactorVoltage is less than 60V or
WeldingDetectionRes is received five times in the correct loop sequence and
VCVCCU_DigitalInput_DebouncedStatus is pressed or
VCVCCU_S3Switch_DeboundedStatus is pressed (only in case of Combo1) or
VCVCCU_Vehicle_StopCharge is pressed (only if feature is activated).