User's Manual
User Manual VC-EVCC
© 2021 Vector Informatik GmbH Version 1.3.0 199
sets the value in the CAN signal VCVCCU_V2G_EVSEMaximumVoltageLimit and
set the value of the CAN signal VCVCCU_V2G_EVSEMaximumVoltageLimitFlag to 1.
5.5.8.19.5 ISO 15118 Response Parameter
The EVSEID of the CurrentDemandRes is ignored.
Remaining data in ISO 15118:
EVSEID
SAScheduleTupleID
MeterInfo (optional)
ReceiptRequired (optional)
5.5.8.20 Metering Receipt
The VC-EVCC proceeds with the MeteringReceiptReq if the following conditions are met.
Charging protocol is ISO 15118
CurrentDemandRes has been received
Payment option “Contract” has been selected
The ReceiptRequired element is included within the CurrentDemandRes message and
set to “TRUE”
The MeterInfo record containing the MeterID is included within the CurrentDemandRes
5.5.8.20.1 DC_EVSEStatus Response Parameter
The CAN signals are filled with the parameters of the MeteringReceiptRes according to the
table below.
MeteringReceiptRes
CAN signal
DC_EVSEChargeParameter.DC_EVSEStatus.
EVSENotification
VCVCCU_V2G_EVSENotification
DC_EVSEChargeParameter.DC_EVSEStatus.
NotificationMaxDelay
VCVCCU_V2G_NotificationMaxDelay
DC_EVSEChargeParameter.DC_EVSEStatus.
DC_EVSEStatusCode
VCVCCU_V2G_EVSEStatusCode
Table 5-60 CurrentDemandRes CAN Signal Mapping (DC_EVSEStatus)
If the MeteringReceiptRes contains
DC_EVSEChargeParameter.DC_EVSEStatus.EVSEIsolationStatus the VC-EVCC
sets the value in the CAN signal VCVCCU_V2G_EVSEIsolationStatus and
sets the value of the CAN signal VCVCCU_V2G_EVSEIsolationStatusFlag to 1.
5.5.8.21 Power Delivery (Renegotiate)
The VC-EVCC proceeds with the PowerDeliveryReq(Renegotiate) if the following conditions
are met.