The CurrentDemandReq uses RemainingTimeToBulkSOC and fills it with the
VCVCCU_V2G_RemainingTimeToBulkSOC CAN signal if
VCVCCU_V2G_RemainingTimeToBulkSOCFlag is 1.
5.5.8.19.3 DC_EVSEStatus Response Parameter
The CAN signals are filled with the parameters of the CurrentDemandRes according to the
table below.
CurrentDemandRes
CAN signal
DC_EVSEChargeParameter.DC_EVSEStatus.
EVSENotification
VCVCCU_V2G_EVSENotification
DC_EVSEChargeParameter.DC_EVSEStatus.
NotificationMaxDelay
VCVCCU_V2G_NotificationMaxDelay
DC_EVSEChargeParameter.DC_EVSEStatus.
DC_EVSEStatusCode
VCVCCU_V2G_EVSEStatusCode
Table 5-58 CurrentDemandRes CAN Signal Mapping (DC_EVSEStatus)
If the CurrentDemandRes contains
DC_EVSEChargeParameter.DC_EVSEStatus.EVSEIsolationStatus the VC-EVCC
sets the value in the CAN signal VCVCCU_V2G_EVSEIsolationStatus and
sets the value of the CAN signal VCVCCU_V2G_EVSEIsolationStatusFlag to 1.
5.5.8.19.4 Common Response Parameter
The CAN signals are filled with the parameters of the CurrentDemandRes according to the
table below.
CurrentDemandRes
CAN signal
EVSEPresentVoltage
VCVCCU_V2G_EVSEPresentVoltage
EVSEPresentCurrent
VCVCCU_V2G_EVSEPresentCurrent
EVSECurrentLimitAchieved
VCVCCU_V2G_EVSECurrentLimitAchieved
EVSEVoltageLimitAchieved
VCVCCU_V2G_EVSEVoltageLimitAchieved
EVSEPowerLimitAchieved
VCVCCU_V2G_EVSEPowerLimitAchieved
Table 5-59 CurrentDemandRes CAN Signal Mapping (Common)
If the CurrentDemandRes contains EVSEMaximumCurrentLimit the VC-EVCC
sets the value in the CAN signal VCVCCU_V2G_EVSEMaximumCurrentLimit and
sets the value of the CAN signal VCVCCU_V2G_EVSEMaximumCurrentLimitFlag to
1.
If the CurrentDemandRes contains EVSEMaximumPowerLimit the VC-EVCC
sets the value with in CAN signal VCVCCU_V2G_EVSEMaximumPowerLimit and
sets the value of the CAN signal VCVCCU_V2G_EVSEMaximumPowerLimitFlag to 1.
If the CurrentDemandRes contains EVSEMaximumVoltageLimit the VC-EVCC