5.5.8.19 Current Demand
The VC-EVCC proceeds with cyclic transmission of CurrentDemandReq if the response
code in the PowerDeliveryRes was OK.
The VC-EVCC extends the request-response loop in state CurrentDemand by a
MeteringReceipt request and response if the following conditions are met.
Payment option “Contract” has been selected
The ReceiptRequired element is included within the CurrentDemandRes message and
set to “TRUE”
The MeterInfo record containing the MeterID is included within the CurrentDemandRes
5.5.8.19.1 DC_EVStatus Request Parameter
The CurrentDemandReq is filled with the content of the received CAN signals according to
the table below.
CurrentDemandReq
CAN signal
DC_EVChargeParameter.DC_EVStatus.EVReady
VCVCCU_V2G_EVReady
DC_EVChargeParameter.DC_EVStatus.EVErrorCode
VCVCCU_V2G_EVErrorCode
DC_EVChargeParameter.DC_EVStatus.EVRESSSOC
VCVCCU_V2G_EVRESSSOC
Table 5-57 CurrentDemandReq CAN Signal Mapping
5.5.8.19.2 Common Request Parameter
The CurrentDemandReq uses EVTargetCurrent and fills it with the
VCVCCU_V2G_EVTargetCurrent CAN signal.
The CurrentDemandReq uses EVTargetVoltage and fills it with the
VCVCCU_V2G_EVTargetVoltage CAN signal.
The CurrentDemandReq uses EVMaximumCurrentLimit and fills it with the
VCVCCU_V2G_EVMaximumCurrentLimit CAN signal if
VCVCCU_V2G_EVMaximumCurrentLimitFlag is 1.
The CurrentDemandReq uses EVMaximumPowerLimit and fills it with the
VCVCCU_V2G_EVMaximumPowerLimit CAN signal if
VCVCCU_V2G_EVMaximumPowerLimitFlag is 1.
The CurrentDemandReq uses EVMaximumVoltageLimit and fills it with the
VCVCCU_V2G_EVMaximumVoltageLimit CAN signal if
VCVCCU_V2G_EVMaximumVoltageLimitFlag is 1.
The CurrentDemandReq uses ChargingComplete and fills it with the
VCVCCU_V2G_ChargingComplete CAN signal
The CurrentDemandReq uses BulkChargingComplete and fills it with the
VCVCCU_V2G_BulkChargingComplete CAN signal if
VCVCCU_V2G_BulkChargingCompleteFlag is 1.
The CurrentDemandReq uses RemainingTimeToFullSOC and fills it with the
VCVCCU_V2G_RemainingTimeToFullSOC CAN signal if
VCVCCU_V2G_RemainingTimeToFullSOCFlag is 1.