If the ChargeParameterDiscoveryRes contains
DC_EVSEChargeParameter.EVSECurrentRegulationTolerance the VC-EVCC
sets the value in the CAN signal VCVCCU_V2G_EVSECurrentRegulationTolerance
sets the CAN signal VCVCCU_V2G_EVSECurrentRegulationToleranceFlag to 1
If the ChargeParameterDiscoveryRes contains
DC_EVSEChargeParameter.EVSEEnergyToBeDelivered the VC-EVCC
sets the value in the CAN signal VCVCCU_V2G_EVSEEnergyToBeDelivered
sets the CAN signal VCVCCU_V2G_EVSEEnergyToBeDeliveredFlag to 1
5.5.8.15.7 Schedule Response Parameter
The VC-EVCC transmits the PMax value of the current PMaxScheduleEntry within the CAN
signals VCVCCU_V2G_CurrentPMaxValue and VCVCCU_V2G_CurrentPMaxMultiplier.
The remaining time of the current PMaxScheduleEntry is calculated by the VC-EVCC with
the help of the RelativeTimeInterval information and transmitted within the CAN signal
VCVCCU_V2G_CurrentPMaxDuration.
The VC-EVCC transmits the PMax value of the subsequent PMaxScheduleEntry within the
CAN signals VCVCCU_V2G_NextPMaxValue and VCVCCU_V2G_NextPMaxMultiplier.
Note
The SalesTariff information of the ChargeParameterDiscoveryRes is not considered by
the VC-EVCC and thus not transmitted on the J1939 vehicle CAN.
5.5.8.16 Cable Check
The VC-EVCC proceeds with the CableCheckReq and sets the ControlPilot_ChargeMode
to mode C if
the response code in the ChargeParameterDiscoveryRes was OK and
Vehicle_ChargePermission is set to allowed and
Vehicle_ContactorStatus is Opened