User's Manual

User Manual VC-EVCC
© 2021 Vector Informatik GmbH Version 1.3.0 191
Note
VCVCCU_V2G_EVMaximumCurrentLimitFlag has to be 1 (already a condition to send
the ChargeParameterDiscoveryReq)
The ChargeParameterDiscoveryReq uses
DC_EVChargeParameter.EVMaximumPowerLimit
and fill with the VCVCCU_V2G_EVMaximumPowerLimit CAN signals if
VCVCCU_V2G_EVMaximumPowerLimitFlag is 1.
The ChargeParameterDiscoveryReq uses
DC_EVChargeParameter.EVMaximumVoltageLimit
and fill with the VCVCCU_V2G_EVMaximumVoltageLimit CAN signals.
Note
VCVCCU_V2G_EVMaximumVoltageLimitFlag has to be 1 (already a condition to send
the ChargeParameterDiscoveryReq)
Caution
The multiplier of the EVMaximumVoltageLimit, EVMaximumCurrentLimit and
EVMaximumPowerLimit must be within the range from -3 to 3.
The ChargeParameterDiscoveryReq uses
DC_EVChargeParameter.EVEnergyCapacity and fill with the
VCVCCU_V2G_EVEnergyCapacity CAN signals if
VCVCCU_V2G_EVEnergyCapacityFlag is 1.
The ChargeParameterDiscoveryReq uses DC_EVChargeParameter.EVEnergyRequest
and fills with the VCVCCU_V2G_EVEnergyRequest CAN signals if
VCVCCU_V2G_EVEnergyRequestFlag is 1.
The ChargeParameterDiscoveryReq uses DC_EVChargeParameter.FullSOC and fill with
the VCVCCU_V2G_FullSOC CAN signals if VCVCCU_V2G_FullSOCFlag is 1.
The ChargeParameterDiscoveryReq uses DC_EVChargeParameter.BulkSOC and fill with
the VCVCCU_V2G_BulkSOC CAN signals if VCVCCU_V2G_BulkSOCFlag is 1.
5.5.8.15.3 ISO 15118 Request Parameter
The ChargeParameterDiscoveryReq uses DC_EVChargeParameter.DepartureTime and fill
with the VCVCCU_V2G_DepartureTime CAN signals if
VCVCCU_V2G_DepartureTimeFlag is 1.
5.5.8.15.4 ISO 15118 Schedule Request Parameter
The ChargeParameterDiscoveryReq sets MaxEntriesSAScheduleTuple depending on the
charging schedules configuration.
Charging Schedules are deactivated: The ChargeParameterDiscoveryReq sets
MaxEntriesSAScheduleTuple to 1.