User's Manual

User Manual VC-EVCC
© 2021 Vector Informatik GmbH Version 1.3.0 178
The signal VCVCCU_ChargeUnit_Mode is set to signal not available if
ControlPilot_PresentStatus is not active or
ControlPilot_PresentStatus is not available or
ControlPilot_DutyCycle is set to signal not available.
If the signal VCVCCU_ChargeUnit_Mode is ChargePwm the ChargeUnit_MaxCurrent is
derived from ControlPilot_DutyCycle (according to table A.6 in [4]).
If the signal VCVCCU_ChargeUnit_Mode is not ChargePwm the ChargeUnit_MaxCurrent is
set to signal not available.
Note
The ChargeUnit_MaxCurrent is calculated with a deviation of ±1A.
5.5.5 Digital Input Control
Signal
Description
DigitalInput_DebouncedStatus
The debounced status of the digital input (charging
stop switch)
DigitalInput_MinPressTime
The minimum time for a valid digital input press event
HighSideOut2_Input_DebouncedStatus
The debounced status of the generic switch input
HighSideOut3_Input_DebouncedStatus
The debounced status of the Terminal 15 signal input
S3Switch_DebouncedStatus
The debounced status of the switch on the gun for
Combo1
Table 5-41 Digital Input Control Signals
Parameter
Value
DigitalInput_MinPressTime
30ms
Table 5-42 Digital Input Control Parameters
Functionality
The different digital inputs are debounced and work as the following. The respective
debounced status signal is set to status pressed if the status of the digital input reports
pressed for DigitalInput_MinPressTime.
The debounced status is set to status not pressed if the status of the digital input reports not
pressed for DigitalInput_MinPressTime.
The DigitalInput_DebouncedStatus is set to error if the status of the digital input reports
error.