Figure 5-3: Electrical Circuit Position Feedback Evaluation
The following table gives an overview of the plug locking considering different start and end
positions.
Situation
Start position
Movement
End position
Lock-A
Bolt is in the no locking position
Lock movement
Bolt is in the locked
position
Lock-B
Bolt is in the no locking position
Lock movement
Bolt is in the no locking
position
Lock-C
Bolt is in the no locking position
Lock movement
Bolt is in the failed locking
position
Lock-D
The bolt is in the failed locking
position
Lock movement
Bolt is in the failed locking
position
Lock-E
The bolt is in the locked position
Lock movement
(ignored)
Bolt is in the locked
position
Table 5-36 Plug Locking Considerations
The VC-EVCC starts to lock the plug (set PlugLock_MotorDrive to direction which closes
the plug) if all following conditions are fulfilled:
Inlet_ConnectionStatus is active
Inlet_UnlockedTime has elapsed
Vehicle_PlugLockAllowed is set
Inlet_MotorStatus is unlocked
PlugLock_MotorStatus is not error