User's Manual

User Manual VC-EVCC
© 2021 Vector Informatik GmbH Version 1.3.0 163
Figure 5-2: Electrical Circuit Proximity Pin Combo1 Inlet
Self-Diagnostics
The VC-EVCC cyclically polls for electrical faults at the proximity pin.
If PlugPresent_Voltage is in one of the valid ranges for normal operation
PlugPresent_SelfDiagnosticStatus is set to OK.
Also, the CAN signals of PlugPresent_Wakeup and PlugPresent_Status are set to error
value if a fault is detected.
If the measured resistance is not in any of the valid ranges for normal operation or known
electrical faults the CAN signals of the respective internal signals are set to value not
available.
PlugPresent_Status
PlugPresent_Resistance
PlugPresent_Wakeup
PlugPresent_SelfDiagnosticStatus