User's Manual
User Manual VC-EVCC
© 2021 Vector Informatik GmbH Version 1.3.0 161
If a cable is connected the VC-EVCC determines the cable resistance value
(PlugPresent_Resistance) from the measured voltage. Possible detectable resistance
values which represent different cable types capable of different charging currents are:
PlugPresent Voltage
PlugPresent Status
Protective Earth Offset
1,15 V
Connected (100 Ohm)
-0,77 V … +2,1 V
1,9 V
Connected (220 Ohm)
-1,58 V … +2,1 V
3,2 V
Connected (680 Ohm)
-2,1 V … +2,1 V
3,85 V
Connected (1500 Ohm)
-2,1 V … +2,1 V
4,65 V
Not connected
-2,1 V … +2,1 V
Table 5-14 PlugPresent Voltage Levels Combo2
Note
The values of the Plug Present Voltage are no real measured values. They are just the
mean of the defined voltage range. A real calculation of the voltage value in software is
too complex.
If no cable is connected the CAN signal for the internal PlugPresent_Resistance signal is
set to not available.
Figure 5-1: Electrical Circuit Proximity Pin Combo2 Inlet