User's Manual

User Manual VC-EVCC
© 2021 Vector Informatik GmbH Version 1.3.0 160
5.3 Low Level Signal Evaluation & Control
5.3.1 Combo-Inlet
5.3.1.1 PlugPresent Evaluation
Note
PlugPresent and Proximity Pin is an alias to each other.
Signal
Description
PlugPresent_Status
The proximity pin connection state of the cable/plug
PlugPresent_Voltage
The voltage measured at the proximity pin
PlugPresent_Resistance
The cable resistance value
PlugPresent_Wakeup
The wakeup state of the proximity pin signal
PlugPresent_SelfDiagnosticStatus
The self-diagnostic state of the proximity pin signal
Table 5-13 Proximity Pin Evaluation Signals
Functionality
Via the proximity pin the ECU starts from sleep mode if a cable is connected.
The VC-EVCC detects the wakeup caused by the proximity pin in the first 75ms after the
wakeup event. If the ECU is already running it cyclically checks if an inlet is connected
(PlugPresent_Wakeup).
Combo2 Inlet
The VC-EVCC interprets the measured voltage (PlugPresent_Voltage) to detect if a cable
is connected (PlugPresent_Status).
Caution
If the value of the internal resistor between PP and PE is configured to 4,7 kOhm, the
VC-EVCC will consider a Combo2 inlet connected and calculate the plug present
voltage accordingly.