User's Manual

User Manual VC-EVCC
© 2021 Vector Informatik GmbH Version 1.3.0 154
5.2.1.4 Fault Memory
The VC-EVCC contains a fault memory which can be handled via UDS according to ISO
14229-1 [7]. The following services are supported by the VC-EVCC.
SID 0x19
Description
19 01
Fault Memory Read (Number)
19 02
Fault Memory Read (all identified)
19 06
Fault Memory Read (extended)
19 07
Fault Memory Report number of DTC by severity
19 08
Fault Memory Read DTC by severity
19 09
Fault Memory Read severity information
19 0A
Fault Memory Read (supported errors)
Table 5-11 Read DTC Information Service (0x19)
SID 0x14
Description
14
Fault Memory Clear (all errors)
Table 5-12 Clear Diagnostic Information (0x14)
The following description explains the reading and clearing of the fault memory with
CANoe/CANalyzer and the delivered CANoe/CANalyzer configuration.
1. Start CANoe/CANalyzer and open the delivered CANoe/CANalyzer configuration
“VC-EVCC”.