Manual Configuration
Reprogramming is also possible without CANoe/CANalyzer. In this case, the following
CAN Messages (UDS/ TP) must be sent on the diagnostic CAN (CAN0) manually:
CAN-Identifier:
Tester --> VC-EVCC, Request: 0x610
VC-EVCC --> Tester, Response: 0x612
Tester --> Functional: 0x614
1. Extended Session:
Request: 02 10 03 FF FF FF FF FF
Response: 06 50 03 00 32 01 F4 FF
2. Tester Present:
Request: 02 3E 00 FF FF FF FF FF
Response: 02 7E 00 FF FF FF FF FF
Caution
The message “Tester Present” has to be sent cyclically in order to keep the VC-EVCC
in the extended session. Otherwise the extended session will be terminated after
approximately 4 – 5 seconds.
3. Three-phase AC charging via LIN:
XX:
- 0x00: Three-phase AC charging is deactivated
- 0x01: Three-phase AC charging is activated
Request: 04 2E FD 22 XX FF FF FF
Response: 03 6E FD 22 FF FF FF FF
Note
In some cases the response message might include the value “AA” instead of “FF”.
In order to read the present three-phase AC charging via LIN configuration, the following
communication has to be executed.
4. Read three-phase AC charging via LIN configuration:
Request: 03 22 FD 22 FF FF FF FF
Response: 04 62 FD 22 XX FF FF FF