Reprogramming is also possible without CANoe/CANalyzer. In this case, the following
CAN Messages (UDS/ TP) must be sent on the diagnostic CAN (CAN0) manually:
CAN-Identifier:
Tester --> VC-EVCC, Request: 0x610
VC-EVCC --> Tester, Response: 0x612
Tester --> Functional: 0x614
1. Extended Session:
Request: 02 10 03 FF FF FF FF FF
Response: 06 50 03 00 32 01 F4 FF
2. Tester Present:
Request: 02 3E 00 FF FF FF FF FF
Response: 02 7E 00 FF FF FF FF FF
Caution
The message “Tester Present” has to be sent cyclically in order to keep the VC-EVCC
in the extended session. Otherwise the extended session will be terminated after
approximately 4 – 5 seconds.
3. Temperature sensor configuration:
XX: PTC Activation
- 0000 000Xb: PTC0 Activation/Deactivation (Off: 0, On: 1)
- 0000 00X0b: PTC1 Activation/Deactivation (Off: 0, On: 1)
- 0000 0X00b: PTC2 Activation/Deactivation (Off: 0, On: 1)
Note
At least one temperature sensor, either PTC1 or PTC2, must be activated for DC
charging.
XX XX: PTC0 Threshold (Resistance value in Ohm)
XX XX: PTC0 Lower Boundary (Resistance value in Ohm)
Request: 04 2E FD 21 XX XX XX XX XX
Response: 03 6E FD 21 FF FF FF FF