User's Manual
User Manual VC-EVCC
© 2021 Vector Informatik GmbH Version 1.3.0 130
5.2.1.2.15 Configuration of Temperature Sensors
The VC-EVCC provides the possibility to activate or deactivate the temperature inputs PTC0
(AC charging) as well as PTC1 and PTC2 (DC charging). Furthermore, the lower boundary
and the threshold of the PTC0 can be configured.
The service structure is defined as 5 bytes.
Byte No.
Bit Pos.
Description
Value
Byte 0
0
PTC0 Activation
Off: 0
On: 1 (default)
Byte 0
1
PTC1 Activation
Off: 0
On: 1 (default)
Byte 0
2
PTC2 Activation
Off: 0 (default)
On: 1
Byte 1 and 2
-
PTC0 Threshold (Resistance value in a
range from 400 to 5000 Ohm)
1500 Ohm (default)
Byte 3 and 4
-
PTC0 Lower Boundary (Resistance value in
a range from 400 to 5000 Ohm)
600 Ohm (default)
Note
An update of the parameter requires a reboot of the VC-EVCC to be applicable.
The diagnostic service “Write Data By Identifier” is only available in the application
extended session.