User's Manual
User Manual VC-EVCC
© 2021 Vector Informatik GmbH Version 1.3.0 128
Manual Configuration
Reprogramming is also possible without CANoe/CANalyzer. In this case, the following
CAN Messages (UDS/ TP) must be sent on the diagnostic CAN (CAN0) manually:
CAN-Identifier:
Tester --> VC-EVCC, Request: 0x610
VC-EVCC --> Tester, Response: 0x612
Tester --> Functional: 0x614
1. Extended Session:
Request: 02 10 03 FF FF FF FF FF
Response: 06 50 03 00 32 01 F4 FF
2. Tester Present:
Request: 02 3E 00 FF FF FF FF FF
Response: 02 7E 00 FF FF FF FF FF
Caution
The message “Tester Present” has to be sent cyclically in order to keep the VC-EVCC
in the extended session. Otherwise the extended session will be terminated after
approximately 4 – 5 seconds.
3. Inlet type configuration:
XX: Lock motor movement time = XX * 10ms
XX XX: Lock motor overload protection time = XX XX * 10ms
XX: Internal PP resistor of the vehicle inlet
- 0x00: 2,7 kΩ
- 0x01: 4,7 kΩ
Request: 04 2E FD 20 XX XX XX XX
Response: 03 6E FD 20 FF FF FF FF
Note
In some cases the response message might include the value “AA” instead of “FF”.
In order to read the present inlet type configuration, the following communication has to be
executed.