User's Manual

User Manual VC-EVCC
© 2021 Vector Informatik GmbH Version 1.3.0 123
5.2.1.2.14 Configuration of Inlet Type
The VC-EVCC provides the possibility to configure the lock motor movement time, the lock
motor overload protection time and the internal proximity pin (PP) resistor of the vehicle inlet.
The service structure is defined as 4 bytes.
Byte No.
Description
Value
Byte 0
Lock motor movement time
600 ms (default)
Byte 1 and 2
Lock motor overload protection time
2650 ms (default)
Byte 3
Internal resistor between PP and PE of the vehicle inlet
CCS Combo 1: 2,7 kΩ
CCS Combo 2: 4,7 kΩ
2,7 kΩ: 0
4,7 kΩ: 1 (default)
The configuration of the PP resistor determines whether the VC-EVCC considers a CCS
Combo 1 or Combo 2 inlet as connected which affects the Proximity Pin evaluation.
Note
An update of the parameter requires a reboot of the VC-EVCC to be applicable.
The diagnostic service “Write Data By Identifier” is only available in the application
extended session.